Construction of a window-wall assembly on a high-rise building involves the installation of completely glazed (unitized) window modules at each floor level. The key detail occurs where the window-wall bypasses the floor slab. Preparation of the edge of the floor slab to provide effective waterproofing and drainage at the floor slab is critical to the performance of these types of glazed systems.